surescan microarray scanner g2600d Search Results


90
Agilent technologies surescan microarray scanner g2600d
Surescan Microarray Scanner G2600d, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/surescan microarray scanner g2600d/product/Agilent technologies
Average 90 stars, based on 1 article reviews
surescan microarray scanner g2600d - by Bioz Stars, 2026-02
90/100 stars
  Buy from Supplier

90
Agilent technologies surescan microarray scanner
Surescan Microarray Scanner, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/surescan microarray scanner/product/Agilent technologies
Average 90 stars, based on 1 article reviews
surescan microarray scanner - by Bioz Stars, 2026-02
90/100 stars
  Buy from Supplier

90
Agilent technologies g2600a surescan microarray scanner system
G2600a Surescan Microarray Scanner System, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/g2600a surescan microarray scanner system/product/Agilent technologies
Average 90 stars, based on 1 article reviews
g2600a surescan microarray scanner system - by Bioz Stars, 2026-02
90/100 stars
  Buy from Supplier

90
Agilent technologies surescan microarray scanner cassette
Surescan Microarray Scanner Cassette, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/surescan microarray scanner cassette/product/Agilent technologies
Average 90 stars, based on 1 article reviews
surescan microarray scanner cassette - by Bioz Stars, 2026-02
90/100 stars
  Buy from Supplier

90
Agilent technologies surescan d microarray scanner
Overview of the field trial and the <t>microarray</t> experimental design. (A) Abiotic and biotic stressors potentially contributing to gill damage of farmed Atlantic salmon. (B) Common reference design microarray experiment. Arrows represent microarrays with the numbers of biological replicates shown next to the arrows. The base of the arrow shows the Cy3-labeled sample (i.e., common reference pool), and the arrowhead shows the Cy5-labeled sample (i.e., experimental sample). This figure was constructed using BioRender ( https://biorender.com/ ).
Surescan D Microarray Scanner, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/surescan d microarray scanner/product/Agilent technologies
Average 90 stars, based on 1 article reviews
surescan d microarray scanner - by Bioz Stars, 2026-02
90/100 stars
  Buy from Supplier

90
Agilent technologies cy3
Overview of the field trial and the <t>microarray</t> experimental design. (A) Abiotic and biotic stressors potentially contributing to gill damage of farmed Atlantic salmon. (B) Common reference design microarray experiment. Arrows represent microarrays with the numbers of biological replicates shown next to the arrows. The base of the arrow shows the Cy3-labeled sample (i.e., common reference pool), and the arrowhead shows the Cy5-labeled sample (i.e., experimental sample). This figure was constructed using BioRender ( https://biorender.com/ ).
Cy3, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/cy3/product/Agilent technologies
Average 90 stars, based on 1 article reviews
cy3 - by Bioz Stars, 2026-02
90/100 stars
  Buy from Supplier

90
Agilent technologies slide holders
Overview of the field trial and the <t>microarray</t> experimental design. (A) Abiotic and biotic stressors potentially contributing to gill damage of farmed Atlantic salmon. (B) Common reference design microarray experiment. Arrows represent microarrays with the numbers of biological replicates shown next to the arrows. The base of the arrow shows the Cy3-labeled sample (i.e., common reference pool), and the arrowhead shows the Cy5-labeled sample (i.e., experimental sample). This figure was constructed using BioRender ( https://biorender.com/ ).
Slide Holders, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/slide holders/product/Agilent technologies
Average 90 stars, based on 1 article reviews
slide holders - by Bioz Stars, 2026-02
90/100 stars
  Buy from Supplier

90
Agilent technologies scan control software
Overview of the field trial and the <t>microarray</t> experimental design. (A) Abiotic and biotic stressors potentially contributing to gill damage of farmed Atlantic salmon. (B) Common reference design microarray experiment. Arrows represent microarrays with the numbers of biological replicates shown next to the arrows. The base of the arrow shows the Cy3-labeled sample (i.e., common reference pool), and the arrowhead shows the Cy5-labeled sample (i.e., experimental sample). This figure was constructed using BioRender ( https://biorender.com/ ).
Scan Control Software, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/scan control software/product/Agilent technologies
Average 90 stars, based on 1 article reviews
scan control software - by Bioz Stars, 2026-02
90/100 stars
  Buy from Supplier

90
Agilent technologies sureprint g3 rat ge 8 60 k v2 microarray
Overview of the field trial and the <t>microarray</t> experimental design. (A) Abiotic and biotic stressors potentially contributing to gill damage of farmed Atlantic salmon. (B) Common reference design microarray experiment. Arrows represent microarrays with the numbers of biological replicates shown next to the arrows. The base of the arrow shows the Cy3-labeled sample (i.e., common reference pool), and the arrowhead shows the Cy5-labeled sample (i.e., experimental sample). This figure was constructed using BioRender ( https://biorender.com/ ).
Sureprint G3 Rat Ge 8 60 K V2 Microarray, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/sureprint g3 rat ge 8 60 k v2 microarray/product/Agilent technologies
Average 90 stars, based on 1 article reviews
sureprint g3 rat ge 8 60 k v2 microarray - by Bioz Stars, 2026-02
90/100 stars
  Buy from Supplier

90
Agilent technologies microarray scanner system
Overview of the field trial and the <t>microarray</t> experimental design. (A) Abiotic and biotic stressors potentially contributing to gill damage of farmed Atlantic salmon. (B) Common reference design microarray experiment. Arrows represent microarrays with the numbers of biological replicates shown next to the arrows. The base of the arrow shows the Cy3-labeled sample (i.e., common reference pool), and the arrowhead shows the Cy5-labeled sample (i.e., experimental sample). This figure was constructed using BioRender ( https://biorender.com/ ).
Microarray Scanner System, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/microarray scanner system/product/Agilent technologies
Average 90 stars, based on 1 article reviews
microarray scanner system - by Bioz Stars, 2026-02
90/100 stars
  Buy from Supplier

90
Agilent technologies gene expression hybridization kit
Overview of the field trial and the <t>microarray</t> experimental design. (A) Abiotic and biotic stressors potentially contributing to gill damage of farmed Atlantic salmon. (B) Common reference design microarray experiment. Arrows represent microarrays with the numbers of biological replicates shown next to the arrows. The base of the arrow shows the Cy3-labeled sample (i.e., common reference pool), and the arrowhead shows the Cy5-labeled sample (i.e., experimental sample). This figure was constructed using BioRender ( https://biorender.com/ ).
Gene Expression Hybridization Kit, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/gene expression hybridization kit/product/Agilent technologies
Average 90 stars, based on 1 article reviews
gene expression hybridization kit - by Bioz Stars, 2026-02
90/100 stars
  Buy from Supplier

Image Search Results


Overview of the field trial and the microarray experimental design. (A) Abiotic and biotic stressors potentially contributing to gill damage of farmed Atlantic salmon. (B) Common reference design microarray experiment. Arrows represent microarrays with the numbers of biological replicates shown next to the arrows. The base of the arrow shows the Cy3-labeled sample (i.e., common reference pool), and the arrowhead shows the Cy5-labeled sample (i.e., experimental sample). This figure was constructed using BioRender ( https://biorender.com/ ).

Journal: Frontiers in Immunology

Article Title: Gill and Liver Transcript Expression Changes Associated With Gill Damage in Atlantic Salmon ( Salmo salar )

doi: 10.3389/fimmu.2022.806484

Figure Lengend Snippet: Overview of the field trial and the microarray experimental design. (A) Abiotic and biotic stressors potentially contributing to gill damage of farmed Atlantic salmon. (B) Common reference design microarray experiment. Arrows represent microarrays with the numbers of biological replicates shown next to the arrows. The base of the arrow shows the Cy3-labeled sample (i.e., common reference pool), and the arrowhead shows the Cy5-labeled sample (i.e., experimental sample). This figure was constructed using BioRender ( https://biorender.com/ ).

Article Snippet: Each microarray slide was scanned at 5 µm resolution using a SureScan D Microarray Scanner (G2600D, Agilent Technologies) using Agilent Scan Control Software (v9.1.11.7, Agilent Technologies) by applying a built-in protocol (Agilent_HD_GX_2color).

Techniques: Microarray, Labeling, Construct

Primers used in the gill either in the preliminary qPCR or the  microarray  validation experiment, including comparison between  microarray  Rank Products and qPCR fold-change results for Atlantic salmon transcripts responsive in moderately damaged gill.

Journal: Frontiers in Immunology

Article Title: Gill and Liver Transcript Expression Changes Associated With Gill Damage in Atlantic Salmon ( Salmo salar )

doi: 10.3389/fimmu.2022.806484

Figure Lengend Snippet: Primers used in the gill either in the preliminary qPCR or the microarray validation experiment, including comparison between microarray Rank Products and qPCR fold-change results for Atlantic salmon transcripts responsive in moderately damaged gill.

Article Snippet: Each microarray slide was scanned at 5 µm resolution using a SureScan D Microarray Scanner (G2600D, Agilent Technologies) using Agilent Scan Control Software (v9.1.11.7, Agilent Technologies) by applying a built-in protocol (Agilent_HD_GX_2color).

Techniques: Microarray, Sequencing, Amplification, Binding Assay

Bar plot of gill transcripts related to gill remodeling and wound healing (panel A–U ). On the lower right side, Panel (V) shows a scatterplot of log 2 fold-change from Rank Products microarray data vs . qPCR log 2 fold-change. Different letters indicate a significant difference between groups using one-way ANOVA. Asterisk (*) shows significance (p< 0.05) between GS0 and GS2 using t-test. Gene symbols followed by a dagger (†) are associated with p-values between 0.05 and 0.10 using either t-test (GS0 vs GS2; i.e., mmp19 ) or one-way ANOVA (i.e., tnnt2 ).

Journal: Frontiers in Immunology

Article Title: Gill and Liver Transcript Expression Changes Associated With Gill Damage in Atlantic Salmon ( Salmo salar )

doi: 10.3389/fimmu.2022.806484

Figure Lengend Snippet: Bar plot of gill transcripts related to gill remodeling and wound healing (panel A–U ). On the lower right side, Panel (V) shows a scatterplot of log 2 fold-change from Rank Products microarray data vs . qPCR log 2 fold-change. Different letters indicate a significant difference between groups using one-way ANOVA. Asterisk (*) shows significance (p< 0.05) between GS0 and GS2 using t-test. Gene symbols followed by a dagger (†) are associated with p-values between 0.05 and 0.10 using either t-test (GS0 vs GS2; i.e., mmp19 ) or one-way ANOVA (i.e., tnnt2 ).

Article Snippet: Each microarray slide was scanned at 5 µm resolution using a SureScan D Microarray Scanner (G2600D, Agilent Technologies) using Agilent Scan Control Software (v9.1.11.7, Agilent Technologies) by applying a built-in protocol (Agilent_HD_GX_2color).

Techniques: Microarray

Results of principal component analysis (PCA) plotted on two dimensions (Panel A ) for the gill differentially expressed microarray log 2 ratio (Cy5/Cy3). PC1 explained 50.72%, PC2 explained 25.49%, and PC3 explained 7.46% of the variability. Panel (B) Bar-plot of the percentage of the explained variance for each PC (dimension). Panel (C) PCA plotted on three dimensions for the gill differentially expressed microarray log 2 ratio (Cy5/Cy3) data.

Journal: Frontiers in Immunology

Article Title: Gill and Liver Transcript Expression Changes Associated With Gill Damage in Atlantic Salmon ( Salmo salar )

doi: 10.3389/fimmu.2022.806484

Figure Lengend Snippet: Results of principal component analysis (PCA) plotted on two dimensions (Panel A ) for the gill differentially expressed microarray log 2 ratio (Cy5/Cy3). PC1 explained 50.72%, PC2 explained 25.49%, and PC3 explained 7.46% of the variability. Panel (B) Bar-plot of the percentage of the explained variance for each PC (dimension). Panel (C) PCA plotted on three dimensions for the gill differentially expressed microarray log 2 ratio (Cy5/Cy3) data.

Article Snippet: Each microarray slide was scanned at 5 µm resolution using a SureScan D Microarray Scanner (G2600D, Agilent Technologies) using Agilent Scan Control Software (v9.1.11.7, Agilent Technologies) by applying a built-in protocol (Agilent_HD_GX_2color).

Techniques: Microarray